Used for the digital photography of patients’ chest, abdomen, bone and soft issue etc.

 

Features

 The floating table with bucky stand can meet the photographic requirements of different standing and lying positions. The bed floating and electromagnetic lock design makes it convenient for the accurate position of the lying patient, operation is much more convenient and flexible.

 The world leading Toshiba 14” *17” OEM digital flat Panel detector can help you get the high-definition images.

  The leading domestic high power compact high frequency X-ray generator and high frequency power inverter makes the machine much more compact and more convenient without the extra high-voltage generator and cable.

  The application of the KV and MA digital closed-loop control technology and the real time control of the microprocessor ensure the accuracy and repeatability of the dose.

  The multiple automatic protection features and fault tips ensure safety during the operation process.

 

Configurations

 

Part Name

 

Qty

Control Console

 

1 unit

HF HV generator

 

1 set

X-ray tube assembly

 

1 unit

Collimator

 

1 unit

Radiography Table

 

1 unit

Bucky Stand

 

1 unit

Flat Panel Detector

 

1 set

Image acquisition Workstation

 

1 set

Display

19 inch LCD display

1 unit

Cables etc accessories

360

1 set

High Frequency Digital Radiography System

SKU: Series : 3001
$73.400,00Preço
Quantidade
  • Item

    Content

    Technical Parameter

    Power Supply

    Voltage

    220V

    Frequency

    50Hz

    Capacity

    ≥40kVA

    internal resistor

    ≤0.15Ω

    Generator

     

    Power Output

    32KW

    Inverter Frequency

    60 KHz

    photography

    Tube Voltage

    40kV—150kV

    Tube Current

    10mA—320mA

    Exposure time

    1.0ms—6300ms

    Digital Controlled X-ray Tube

     

    Tube Focus:Large Focus/Small Focus

    1.2mm /0.6mm

    Input Power

    Big focus 40kW /  Small Focus 20kW

    thermal capacity

    110KJ

    Rotary anode speed

    2800rpm

    Radiography Table

    Table longitudinal movement 

    ≥900mm

    Table transverse movement

    ≥220mm

    Pillar movement along table

    ≥1300mm

    Detecting holder movement

    ≥500mm

    Tube assembly up-down movement

    500mm1280mm

    Collimator         

    Manual Multi-leaf

    Table use fixed grid

    Grid density 103L/INCH, grid 10:1   SID: 120cm, fixed model: 15″×18″

     

    Bucky Stand

    Radio-graphic device movement along pillar 

    ≥1300mm

    Cassette SID:

    450 1780mm

    Fixed grid:

    Grid density 103L/INCH, grid 10:1  SID 180cmSize: 15″×18″

    Flat Panel Detector

    Vision size358mm(H)×430 mm(V)

    Pixel Matrix2560(H)×3072(V)

    Pixel gap139 μm

    Imaging timeless than 10s

    Limiting resolution3.5 lp/mm typ

    A / D transform14 bit

    Energy range40 - 150 kVp

    Biggest input doselow transmission gain): 4 mR / frame

    Date outA 16-bit digital output Ethernet1000BASE - T

    Command controlEthernet1000BASE - T

    Power input DC 24V  4.8A

    Work Station

    CPU System

    Brand: DELL OPTIPLEX 7010 commercial use

    ProcessorCore™ i5-3570 processor

    RAM4GB  DDR3

    Hardware500GB  SATA (7200 rpm)

    CD-driversuit MT’s 16X variable-speed  DVD + / - RW With functions of double written

    Network Card: Broadcom NetXtreme 10/100/1000 PCIe Gigabit LAN GNTB-A

    , High display card: 1GB AMD RADEON HD 7570,FH,with DVI-VGA Adapter

    Slop: PCIE seriel port and parallel port, all height, MT

    Color LCD Monitor

    19 inches 1M LED backing light LCD display, revolution1280x10245:4screendot pitch0.294mm, contrast ratio: 1000:1, brightness: 250cd/, Grey feedback time5ms visual Angle: 160/170°

     Monochrome MonitorOptional)

    1280*1024,19inchesbrightness 1000cd/m2, Contrast Ratio 9001

    Work Station Software

    Basic operation: change control console password, edit ID, acquisite images.     

    Additional operation:Add new check, edit present checking info, add new position, change image aquisition order, multi-checking agreement chance, manual adjustment of exposure parameters, automatic exposure control mode, focus choice, patient body-type choice, tube capacity check, ESA curve choice, image cutting, note added (sent to DICOM workstation) , mark on images, rotate or overturn, full-size image observation, check patient info and dose info, accept or refuse images.

    Image management: change order, patient basic info editing, inquiry history images, resend history images, re-print history images, check images mark info, review history images, manage refused images, space reclaimed, image protection, and manual image deletion etc.

    System managementID edition, change ID password, ED refrigeration set, statistics info checking, detector calibration, equipment control, output order management, image measurement.

bottom of page