Technical Specifications
PHOTOMETRIC MODULE
Seven Narrowband Interference Filters
Filter Wavelengths: 340, 405, 505, 546, 578, 630 and
670nm (1 open position for optional filter)
IAD process ensures long filter life
Wavelength Accuracy : ±2nm
Silicon Photo Diode detector
Absorbance Range : 0.0 – 3.0 A
Photometric Drift : < 5 mAbs/30min
Filter Wavelengths: 340, 405, 505, 546, 578, 630 and
670nm (1 open position for optional filter)
Resolution : 0.0001 Absorbance Units
CV : < 1%
TEMPERATURE OF FLOW CELL/CUVETTE
25°C, 30°C, 37°C
Temperature Stability : ± 0.2°C
DISPLAY
5.7 Inch LCD display screen
High Contrast Display
KEYBOARD
Tactile touch QWERTY keypad
Visual indication on keypad during aspiration
PRINTER
Internal 57mm thermal printer with full graphics
printing
MEASURING MODULE
Dual mode ( Flow cell & Cuvette)
30 μl Flowcell volume
External cuvettes (10mm path length)
High quality Quartz flow cell for precise measurements
Peltier-controlled reaction temperature
REACTION VOLUME
Minimum aspiration volume - 300μl
Maximum aspiration volume - 5ml
DIMENSIONS
Length : 422mm • Height : 176mm
Width : 324mm • Weight : 6.5 kg
ANALYSIS METHOD
Sample blanking and Reagent Blanking
Endpoint, Fixed time and Kinetic
TEST PROFILES
User defined 10 Test Profiles
10 tests can be added in each profile
TEST CHANNELS
48 dedicated assays
Open channel capability
200 Programmable channels
Direct access keys for dedicated assays
DATA MANAGEMENT
Storage of up to 10,000 test results
Stores 30 days QC for each Assay
Reagent Blank storage
REPORTS
Search by date, sample ID or Test Name
Calibration Reports, QC results
UNITS
15 pre-defined measurement units
QC AND CALIBRATION
Daily and monthly QC with data archiving
INTERFACE
RS 232 Port • USB Port
PC Connectivity (optional)
POWER
Input Voltage Range : 88 - 264 VAC
Frequency Range : 47 - 63 Hz
Power consumption : 75 W max
FLEXIBLE
Programmed to analyse endpoint, fixed time and kinetic assays
Storage for 200 user programmable test methods and 10000 test results
Create up to 10 customised test profiles
ECONOMICAL
Low reagent consumption
Extended lamp life
High quality surface coating ensures long Filter life
ROBUST
Low maintenance
Consistent and reliable results
Indian design and manufacturing
OPTIMISED OPTICAL DESIGN
High sensitivity measurements for kinetic and turbidimetric assays (RF, ASO, CRP etc)
INTUITIVE USER INTERFACE
Six informative screens control operations
Easy navigation through submenus
Requires minimal training
QUALITY CONTROL
Mean, SD, % CV and R calculated for each assay
Levey-Jennings control chart
Westgard Rules
3 levels per assay
CALIBRATION
Factor, one-point, two-point and multi-point
Up to 3 replicates per point
Up to 10 calibration points
Non linear multi point calibration
ERROR DETECTION
Early detection and reporting of errors on screen
Saves time and avoids faulty test runs which saves
reagents
ANALYSIS MODES
Absorbance : Kinetic with factor and linearity check
Immunoturbidimetry
End Point with factor, standard or multiple standards with or without
reagent/sample blank
Bichromatic mode
Fixed time with standard, factor or multiple standards, with or without
reagent blank